4. Effective container treatment
|
|
Bottle sterilization with PAA
- Bottle internal and external surfaces are
sterilized with spraying of liquid PAA.
- Bottles are rinsed with sterile water.
- Strong mechanical & chemical action for bottles
treatment to be effective on removal action on Cold Spot contamination.
- Short treatment times.
- Penetrating nozzles for high flow rate.
- Recovery of PAA.
- Suitable for HA and LA beverages.
- FDA approved
- High line availability no intermediate SOP: 120h in HA
production, 72h in LA production.
Bottle sterilization with H2O2
- Bottles are turned upside down and sterilized by maximized H2O2 chemical
action.
- No water consumption during production. Bottle are rinsed with sterile hot
air purging.
- Available for high acid products.
- Up to 72 hours continuous production with NO intermediate SOP cycle.
Caps sterilization
- Sterilizable caps:
- PAA spray sterilization of cap
internal/external surfaces.
- E-Beam sterilization of cap
internal/external surfaces.
- Presterilized caps:
- Bag tunnel: bags are sterilized with PAA
spray
- Sterilbag: bags are sterilized with VHP
|
|